In this guide
Engineering tables
The rows your structural checks are decided by, each with the standard, table and basis it came from.
What it is
Engineering tables are the figures Base's structural checks are decided by, kept as rows: span tables, bracing capacities, tie-down connectors, wind classification, footings, pergola and canopy members, deck members and sheeting spans. There is a tab for each.
Every row says where it was read from (the standard or the maker's document, its edition, the table and the clause) and its basis:
- Licensed copy: you read it off your own copy of the standard.
- Supplier data: the maker's published data sheet.
- Engineer-verified: an engineer checked it, and the row names them.
- Derived: anything else. A figure from a secondary source, a row carried over from Framing settings, or one of Base's built-in tables.
The basis matters. A check decided by a licensed, supplier or engineer-verified row can stand as deemed-to-satisfy. A check decided by a derived row goes to your engineer for certification instead, and the drawings say so.
Before you start
- The page is listed for admins, and importing or superseding rows needs an admin. Anyone in the organisation can read the rows the designer uses.
- Have the document in front of you. A licensed row must give the edition and the table; an engineer-verified row must name the engineer.
- Base does not include AS 2870 or any other paid standard. Footing rows are yours to enter, from your own copy or your engineer's.
How to
Import rows from a spreadsheet
- Open the tab for the kind of row (for example Span tables).
- Press Template to download a CSV with the right columns: label, standard, edition, table, clause, basis, verified_by and note, then the figures for that kind.
- Fill in one row per figure, save it as CSV, and press Import CSV.
- Base reads the file and tells you how many rows it found and which columns it ignored. Press Import 12 rows (the button counts them) to save them, or Cancel.
- If any line is wrong, nothing is imported. Base lists each refused line by number and what is wrong with it; fix them and import the file again.
Replace a row
Import a row with the same key (the same member, section and spacing for a span row; the same key for a bracing system or connector). The new row becomes the live one and the old one is kept as Superseded.
Stop using a row
Press Supersede on the row. The frame designer stops reading it. Turn on Show superseded to see retired rows, and press Restore to bring one back; Base will not restore a row while another live row has the same key.
What happens on its own
- The frame designer reads the live rows of each kind on every design. A tab with no rows of your own falls back to what the designer used before: the rows in Framing settings, or Base's built-in pergola and deck tables. Those are shown below your rows, marked Derived.
- When your organisation's database has not yet been updated for engineering tables, the page says so and shows the Framing settings rows the designer is reading. Designs keep working either way.
- On a job's foundation, the footing row you have entered for the site class is named on the Foundation tab with whether it stands as deemed-to-satisfy.
- A Pergola & canopy row with the role blade is a louvre blade span from the supplier's table (the section is the blade's name). The pergola designer offers it under Blade span (supplier row) on a louvre roof.
Things that surprise people
- Rows you entered in Framing settings before this page existed came across as Derived, even ones you had ticked as verified. Re-import them with the standard, table and basis to let them stand as deemed-to-satisfy.
- Once a tab has rows of your own, the designer reads those and no longer reads that kind from Framing settings.
- Nothing is ever deleted. A superseded row stays, so a check made from it can still say where its number came from.
- Base's built-in pergola and deck tables are sourced from published industry tables, but they count as derived until you enter your own.
Related
- Framing settings: your roll former, costing and default wind class
- Frames: the frame designer and its Foundation tab